ADC-AES8 Rev. 1
nevion.com | 9
6 FLP4 commands
FLP stands for Flashlink Protocol. The current revision of this protocol is 4, hence FLP4. This
specification is available from Nevion Support.
The following FLP4 block commands are used in the monitoring and control of the module.
ablk
pwr
6.1 ablk
The „ablk‟ blocks correspond to the physical audio ports as follows.
Blocks 0 to 3 report and accept the „lvl‟ keyword followed by the maximum input level in cBu
(dBu multiplied by 10).
i.e. ablk 0 lvl 240 cBu
Blocks 4 to 6 report input presence with the „freq‟ keyword followed by the received sample
frequency or 'los' or 'lol'. Absence of signal is reported with 'los' while 'lol' indicates an
unrecognized sample frequency.
i.e. ablk 4 input freq 44 kHz
6.2 pwr
The „pwr‟ blocks from 0 to 4 list the levels of the power supplies as measured by the
microcontroller.
0 is the frame +5V
1 is analogue +4.8V
2 is the frame +15V
3 is the frame -15V
4 is digital +3.3V
The frame supplies are measured after the module fuses and filtering.
6.3 On-site re-programming
The module may be re-programmed on site with a GYDA Multicon system controller.
Firmware will be provided by Nevion support when necessary.