Table 793-1. Display T3 CES Card Status Definitions, continued
ITEM STATUS DEFINITION ACTION
DS3 Line Status No Alarm
Xmit AIS
LOS
Loopback
State
Other Failure
T3 line is operating within
normal parameters.
Card is transmitting an AIS
signal.
No input signal being
received.
Card has been manually set to
loop signal back to customer
equipment.
Card is experiencing a failure
other than these listed.
No action required.
Check local T3 signal input.
Check metallic input and DSX.
Check customer end for
troubleshooting activity. If required,
release loopback per DLP-772.