ADC Telecommunications, Inc.
44 C
HAPTER 1: HARDWARE OVERVIEW
Table 1-5 1000BASE-LX Transmission Ranges
In addition to the common module components found on each application
module, each Gigabit Ethernet SpectraFlow module includes an LED display
that provides these port status:
Figure 1-12 shows a Gigabit Ethernet SpectraFlow module. For a description
of each numbered callout, see Table 1-2 on page 26.
Fiber Type
Diameter
(microns)
Wavelength
(Nanometers)
Transmission
Distance
Optical
Output Power
Input
Sensitivity
Single mode 9 1300 10 kilometers Min: -9.5 dBm
Max: -3 dBm
Min: -20 dBm
Max: -3 dBm
Status Description
Tx Indicates the module is transmitting a Gigabit Ethernet
packet from the module.
Rx Indicates the module is receiving a Gigabit Ethernet
packet.
LINK Indicates a valid connection to the network. Illuminates
when a MAC-layer link is detected.
SIG DET (Signal
Detect)
Indicates a valid signal is detected. Illuminates when
optical energy is detected.