Figure 33: VSYS Valid Input Power Detection
Table 46: VSYSREF Denition
Parameter Description Min Typ Max Unit
VSYSREFH VSYS Rising Threshold (VSYS: L->H) 2.975 3.0 3.035 V
VSYSREFL VSYS Falling Threshold (VSYS: H->L) 2.675 2.70 2.725 V
tDEBOUNCE VSYS comparator debouncing time 90 100 110 ms
12.3 VBUS Power Source Detection
TheVBUSPowerSourceDetectorisusedtoindicatewhenthevoltagelevelontheVBUSpinhassettledabove~940mV.
Figure 34: USB Detection
VBUSRising(ConnectionEvent)
WhentheVBUS levelat thecomparatorbecomeshigherthan thereferencevoltage (includingrisingedgehysteresis),
VBUSis consideredvalid.If theVBUSDBEN bitis setinthe VBUSDETCTRLregister,VBUS mustbe sensedas valid
for the full 100ms de-bounce time beforethe SVBUSDET bit in the SPWRSRCIRQ register is set, indicating charger
connection.IfVBUSDBENiscleared,SVBUSDETissetimmediatelyuponVBUSbecomingvalid.
VBUSFalling(DisconnectionEvent)
WhentheVBUSlevelatthecomparatorbecomeslowerthanreferencevoltage(includingfallingedgehysteresis),VBUS
isconsideredinvalid. Ifthe VBUSDBEN bitis set inthe VBUSDETCTRLregister, VBUSmust besensedas invalidfor