MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
82
MYXPM6021*
Form #: CSI-D-685 Document 011
CH Description Signal Name Measurement
Range
Condition Comment ADC Value Gain
6 System Temp 1
(Pin: SYSTHERM1)
ADCIN5 0.0V ..
VLP
No VREFT needs to be switched on 1ms
prior to ADC measurement.
Vin/VREF
T*1023
1
7 System Temp 2
(Pin: SYSTHERM2)
ADCIN6 0.0V ..
VLP
No Vin/VREF
T*1023
1
8 VSYS
(Pin: VSYS)
VSYS 2.5V ..
5.5V
Yes 0.8*(VSYS -
VLP)/VLP*
1023
0.8
9 Averaging Output Current ADCIN7 0.0V ..
VLP
Yes There is a pre-selection on
which rail the current measurement
will be averaged
2*Vin/VRE
F*1023
2
Table51:ADCChannelOverview (continued)