(D) BEPT-X-T 25, 50 or 100 pair 110 block 110 block
BEPT-X-CF 25, 50 or 100 pair 710 connector 110 block
BEPT-X-MM 25, 50 or 100 pair 3M connector 110 block
BEPT-X-SC-Y 25, 50 or 100 pair 6’, 12’ or 25’ stub 110 block
BEPC-X-C 25, 50 or 100 pair 66 block 66 block
BEPC-X-CF 25, 50 or 100 pair 710 connector 66 block
BEPC-X-MM 25, 50 or 100 pair 3M connector 66 block
BEPC-X-SC-Y 25, 50 or 100 pair 6’, 12’ or 25’ stub 66 block
47
The Service Provider
Solutions Guide
800-825-5517 (7 a.m. – 5 p.m. CT) www.graybar.com
Power & Protection
E
D
BEP SERIES BUILDING ENTRANCE PROTECTORS
Catalog # Description Input Output
PROTECTION MODULES
(E) R3B1E Gas protector without heat coil
R4B1E Gas protector with heat coil
R3B1EJZ Super-duty gas protector without heat coil
R4B1EJZ Super-duty gas protector with heat coil
R3B1S Solid-state protector without test coil
R4B1S Solid-state protector with test coil
Catalog # Description
Pair count: X= 25, 50 or 100
Stub length (ft.): Y= 6, 12 or 25
Supplier Prefix: RUP
Building Entrance Protection (BEP)
BUILDING ENTRANCE TERMINALS (BETS)
110 connector, 66 block or cable stub connections, protects up to 100 lines
•Wall or frame mountable, stackable to allow for future service expansion
•Internal splice chamber and covers over incoming and outgoing connections
External three-position ground connectors accept 6-14 AWG ground wire
Equipped with an internal fuse link
•Accommodates industry-standard 5-pin protection modules
•Designed to exceed the requirements set forth in Underwriters Laboratories UL 497
PROTECTOR MODULES
•Gas or solid state
•Heavy-duty surge handling capability and balanced operation
•Available with or without PTC sneak-current protection
•Integrated test points
Rugged, dependable operation
•Documented safe performance, prevents damage by lagging or sneak transients
•Nonradioactive
•UL/cUL Listed and an ISO 9002 certified manufacturer
C
A
(A) 1880B1-100 100-pair BET, 25’ 26 AWG cable input, 110 connection output
(B) 1880ECA1-100G 100-pair BET, 110 connection input and output with cover and
splice chamber
(C) 1890ECT1/NSC-100G 100-pair BET, 66 block connection input and output with cover
(D) 1900A1-100 100-pair BET, 25’ 26 AWG cable input, 25’ 24 AWG cable output
(E) 2625QC/QC 25-pair BET, 66 block connection input and output
(F) C3B1E 350V gas protector module
C4B1E 350V gas protector module with PTC sneak-current protection
(G) C3B1S-BAL 300V solid-state protector module
C4B1S-BAL 300V solid-state protector module with PTC sneak-current protection
Catalog # Description
E
F
G
Supplier Prefix: CUZ
B
D
Vista de pagina 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 79 80

Comentarios a estos manuales

Sin comentarios